10.1 Utility Functions
10-9
10
* 1. Normally set to “0.” When using an external regenerative resistor, set the capacity (W) of the regenerative resistor.
* 2. The upper limit is the maximum output capacity (W) of the SERVOPACK.
Pn534 Program JOG Acceleration/Deceleration
Time
2 to 10000 ms 1 ms 100 ms Immedi-
ately
−
Pn535 Program JOG Waiting Time 0 to 10000 ms 1 ms 100 ms Immedi-
ately
−
Pn536 Number of Times of Program JOG Move-
ment
1 to 1000 times 1 time 1 time Immedi-
ately
−
Pn550 Analog Monitor 1 Offset Voltage -1000.0 to 1000.0 V 0.1 V 0.0 V Immedi-
ately
8.2
Pn551 Analog Monitor 2 Offset Voltage -1000.0 to 1000.0 V 0.1 V 0.0 V Immedi-
ately
Pn600
Regenerative Resistor Capacity
∗1
Depends on
SERVOPACK Capac-
ity
∗2
10 W 0 W Immedi-
ately
−
Parameter
No.
Name Setting Range Units
Factory
Setting
Setting
Validation
Reference
Section
SIEPS80000025.book 9 ページ 2004年10月25日 月曜日 午前11時57分