116
Data
• Reference Data (available to read out/write in)
Note: Write in “0” for unused bit. Never write in data for the reserved register.
Register
No.
Bit Description
0000H Reserved
0001H
0 RUN command 1: Run 0: Stop
1 Reverse run 1: Reverse run 0: Forward run
2 External fault 1: Fault (EFO)
3 Fault reset 1: Reset command
4 Multi-function input reference 1 (Function selected by n050)
5 Multi-function input reference 2 (Function selected by n051)
6 Multi-function input reference 3 (Function selected by n052)
7 Multi-function input reference 4 (Function selected by n053)
8 Multi-function input reference 5 (Function selected by n054)
9 Multi-function input reference 6 (Function selected by n055)
A Multi-function input reference 7 (Function selected by n056)
B-F (Not used)
0002H Frequency reference (unit: n152)
0003H V/f gain (1000/100 %) Setting range: 2.0 to 200.0 %
0004H-
0008H
Reserved
0009H
0
Multi-function output reference 1
(Effective when n057=18)
(1: MA ON 0: MA OFF)
1
Multi-function output reference 2
(Effective when n058=18)
(1: P1 ON 0: P1 OFF)
2
Multi-function output reference 3
(Effective when n059=18)
(1: P2 ON 0: P2 OFF)
3-F (Not used)
000AH-
001FH
Reserved

Table of Contents

Related product manuals