140
READ Function
Reads out the constants in batch from the Inverter and stores them in
EEPROM inside the Digital Operator. When the read-out is executed,
the previously stored constants data in the EEPROM are cleared and
replaced with the newly entered constants.
Example: Storing Constants from Inverter in EEPROM in Operator
Explanation Operator Display
• Enable the set-
ting of constants
n001 to n179.
Press to lit
.
Press to dis-
play the set value.
Change the set value to
4 by pressing the or
key.
• Press .
(May be a different constant No.)
(Lit)
(May be a different set value.)
(Flashes)
(Lit for one second.)
(The constant No. is displayed.)
• Set Contant
Read Prohibited
Selection (n177)
to read-enabled.
*1
Change the constant No.
to n177 by pressing the
or key.
Press to dis-
play the set value.
Change the set value to
1 by pressing the or
key.
• Press .
(Lit)
(Flashes)
(Lit for one second.)
(The constant No. is displayed.)
DSPL
PRGM
ENTER
ENTER
ENTER
ENTER