6. Programming Features
63
When operating with frequency larger than 60/50 Hz, change only the
Max. Output Frequency (n011).
Switching LOCAL/REMOTE Mode
The following functions can be selected by switching LOCAL or
REMOTE mode. To select the RUN/STOP command or frequency ref-
erence, change the mode in advance depending on the following appli-
cations.
• LOCAL mode: Enables the Digital Operator for RUN/STOP com-
mands and FWD/REV RUN commands. The fre-
quency reference can be set using the potentiometer
or .
• REMOTE mode: Enables RUN Command Selection (n003).
The frequency reference can be set using the Fre-
quency Reference Selection (n004).
Constant torque
Constant output or
variable output
Base point
n013
=60 or 50 Hz
n011
=90 Hz
n
012
=
200 V