52
Simple Data Setting
Digital setting (refer to 5. Operating the Inverter) and potentiometer
setting are both possible for simple acceleration/deceleration operation
of the VS-606V7.
Digital setting is set at the factory (n004=0). For the model with JVOP-
147 Digital Operator (without potentiometer), factory setting is set by
frequency setting potentiometer (n004=1).
Following is an example in which the function indicators are used to set
frequency reference, acceleration time, deceleration time, and motor
direction.