6. Programming Features
139
Prohibiting Constant Read Selection (n177)
Select this function to prevent accidentally overwriting the constants
stored in EEPROM in the Digital Operator. Reading is not possible
when this constant is set to 0.
The constant data stored in the Digital Operator are safe from accidental
overwriting.
If reading is attempted while this constant is set to 0, PrE will flash.
Press or and return to the constant No. display.
Constant
No.
Name Unit Setting Range Factory
Setting
n176 Constant
Copy Func-
tion Selection
- rdy: READY
rEd: READ
CPy: COPY
vFy: VERIFY
vA: Inverter capacity display
Sno: Software No. display
rdy
Constant
No.
Name Unit Setting Range Factory
Setting
n177 Constant Read
Selection Prohibit
- 0: READ prohibited
1: READ allowed
0
DSPL
ENTER

Table of Contents