196
Note: Remove the top and bottom covers so that Inverters of 5.5/7.5 kW (200/
400-V Classes) can be used as IP00.
200 V
single-
phase
0.1 68 128 76 56 118 5 M4 0.6 3.7 10.4 14.1 1
0.2 68 128 76 56 118 5 M4 0.7 7.7 12.3 20.0 1
0.4 68 128 131 56 118 5 M4 1.0 15.8 16.1 31.9 1
0.75 108 128 140 96 118 5 M4 1.5 28.4 23.0 51.4 2
1.5 108 128 156 96 118 5 M4 1.5 53.7 29.1 82.8 2
2.2 140 128 163 128 118 5 M4 2.2 64.5 49.1 113.6 2
3.7 170 128 180 158 118 5 M4 2.9 98.2 78.2 176.4 2
400 V
3-phase
0.2 108 128 92 96 118 5 M4 1.0 9.4 13.7 23.1 2
0.4 108 128 110 96 118 5 M4 1.1 15.1 15.0 30.1 2
0.75 108 128 140 96 118 5 M4 1.5 30.3 24.6 54.9 2
1.5 108 128 156 96 118 5 M4 1.5 45.8 29.9 75.7 2
2.2 108 128 156 96 118 5 M4 1.5 50.5 32.5 83.0 2
3.0 140 128 143 128 118 5 M4 2.1 58.2 37.6 95.8 2
3.7 140 128 143 128 118 5 M4 2.1 73.4 44.5 117.9 2
5.5 180 260 170 164 244 8 M5 4.8 168.8 87.7 256.5 3
7.5 180 260 170 164 244 8 M5 4.8 209.6 99.3 308.9 3
Voltage
class
Capaci-
ty (kW)
W H D W1 H1 H2 d Mass Heat Loss (W) Fig.
Heat-
sink
Unit Total

Table of Contents