9. Specifications
201
018 0112 Selecting Setting Unit for Ac-
celeration/deceleration Time
0, 1 - 0 No 72
019 0113 Acceleration Time 1 0.00 to 6000 s Depend on
n018 setting
10.0 s Yes 71
020 0114 Deceleration Time 1 0.00 to 6000 s Depend on
n018 setting
10.0 s Yes 71
021 0115 Acceleration Time 2 0.00 to 6000 s Depend on
n018 setting
10.0 s Yes 71
022 0116 Deceleration Time 2 0.00 to 6000 s Depend on
n018 setting
10.0 s Yes 71
023 0117 S-curve Selection 0 to 3 - 0 No 73
024 0118 Frequency Reference 1 (Mas-
ter Frequency Reference)
0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
6.00 Hz Yes 67
025 0119 Frequency Reference 2 0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
0.00 Hz Yes 67
026 011A Frequency Reference 3 0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
0.00 Hz Yes 67
027 011B Frequency Reference 4 0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
0.00 Hz Yes 67
028 011C Frequency Reference 5 0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
0.00 Hz Yes 67
029 011D Frequency Reference 6 0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
0.00 Hz Yes 67
030 011E Frequency Reference 7 0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
0.00 Hz Yes 67
No. Register
No. for
Trans-
mission
Name Setting Range Setting Unit Factory
Setting
Change
during
Opera-
tion
User
Set-
ting
Ref.
Page