56
appears on the display for one second and the set data
returns to its initial values in the following cases.
1. If the set values of Multi-function Input Selections 1 to 7
(n050 to n056) are the same
2. If the following conditions are not satisfied in the V/f pat-
tern setting:
Max. Output Frequency (n011) Max. Voltage Output
Frequency (n013)
> Mid. Output Frequency
(n014)
Min. Output Frequency
(n016)
For details, refer to Adjusting Torque According to Appli-
cation (V/f Pattern Setting) on page 57.
3. If the following conditions are not satisfied in the jump
frequency settings:
Jump Frequency 3 (n085) Jump Frequency 2 (n084)
Jump Frequency 1 (n083)
4. If the Frequency Reference Lower Limit (n034) Fre-
quency Reference Upper Limit (n033)
5. If the Motor Rated Current (n036) 150% of Inverter
rated current
6. If constant n018 is set to 1 (Acceleration/Deceleration
Time Unit is 0.01 s) when n018 is set to 0 (Acceleration/
Deceleration Time Unit is 0.1 s) and a value exceeding
600.0 s is set for an Acceleration/Deceleration Time (n019
to n022)