6. Programming Features
93
Example: Set n003=1, n004=2, n008=0.
Open: Run according to the frequency reference from multi-function
input terminal FR and RUN command from multi-function
input terminals S1 to S7.
Closed: Run according to the potentiometer frequency reference and
RUN command from the Digital Operator.
UP/DOWN Commands (Setting: n056 = 34)
When the FWD (REV) RUN command is ON, acceleration/deceleration
is enabled by inputting the UP or DOWN signal from multi-function
input terminals S6 and S7 without changing the frequency reference.
Operation can thus be performed at the desired speed. When UP/
DOWN commands are specified in n056, any function set in n055 is
disabled, terminal S6 is the input terminal for the UP command, and ter-
minal S7 is the input terminal for the DOWN command.
Timechart for UP/DOWN Command Input
Multi-function Input Termi-
nal S6 (UP command)
Closed Open Open Closed
Multi-function Input Termi-
nal S7 (DOWN command)
Open Closed Open Closed
Operation Status Accel-
eration
Decel-
eration
Hold Hold
FWD RUN
UP Command S6
DOWN Command S7
Upper Limit Speed
Lower Limit Speed
Output Frequency
Frequency Agree
Signal
U = UP (accelerating) status
D = DOWN (decelerating) status
H = HOLD (constant speed) status
U1 = UP status, clamping at upper limit speed
D1 = DOWN status, clamping at lower limit speed