App.2-11
IM CW240E
Appendix
App
Appendix 2 File/Print Item Descriptions
Category Header Characters Unit
Total Value
THD-F
(Selection)
THD-R
(Selection)
3P3W
3P3W
1P3W
3P3W
1P3W
1P3W
Harmonic Measurement Data (3P3W+1P3W)
Content
V
TOTAL_U2_INST(V)_3P Voltage 2 total value (1st to 50th order)
TOTAL_U1_INST(V)_3P Voltage 1 total value (1st to 50th order)
TOTAL_U3_INST(V)_3P Voltage 3 total value (1st to 50th order)
V
TOTAL_U1_INST(V)_1P Voltage 1 total value (1st to 50th order)
TOTAL_U2_INST(V)_1P Voltage 2 total value (1st to 50th order)
A
TOTAL_I1_INST(A)_1P Current 1 total value (1st to 50th order)
THDF_U1_INST(%)_3P Voltage 1 total harmonic distortion factor
TOTAL_I2_INST(A)_1P Current 2 total value (1st to 50th order)
A
W
TOTAL_I2_INST(A)_3P Current 2 total value (1st to 50th order)
TOTAL_I1_INST(A)_3P Current 1 total value (1st to 50th order)
TOTAL_I3_INST(A)_3P Current 3 total value (1st to 50th order)
TOTAL_P_INST(W)_3P
• Harmonic order 01 to 50 is entered for n.
• For the average value, INST becomes AVE.
• For the maximum value, INST becomes MAX.
• For the minimum value, INST becomes MIN.
Electric power total value (1st to 50th order)
THDF_U1_INST(%)_1P Voltage 1 total harmonic distortion factor
W
%
THDF_U2_INST(%)_3P Voltage 2 total harmonic distortion factor
THDF_U3_INST(%)_3P Voltage 3 total harmonic distortion factor
THDF_I1_INST(%)_3P Current 1 total harmonic distortion factor
THDF_I2_INST(%)_3P Current 2 total harmonic distortion factor
THDF_I3_INST(%)_3P Current 3 total harmonic distortion factor
THDF_U2_INST(%)_1P Voltage 2 total harmonic distortion factor
THDF_I1_INST(%)_1P Current 1 total harmonic distortion factor
THDF_I2_INST(%)_1P Current 2 total harmonic distortion factor
THDR_U2_INST(%)_3P Voltage 2 total harmonic distortion factor
THDR_U3_INST(%)_3P Voltage 3 total harmonic distortion factor
THDR_I1_INST(%)_3P Current 1 total harmonic distortion factor
THDR_I2_INST(%)_3P Current 2 total harmonic distortion factor
THDR_I3_INST(%)_3P Current 3 total harmonic distortion factor
THDR_U2_INST(%)_1P Voltage 2 total harmonic distortion factor
THDR_I1_INST(%)_1P Current 1 total harmonic distortion factor
THDR_I2_INST(%)_1P Current 2 total harmonic distortion facto
THDR_U1_INST(%)_1P Voltage 1 total harmonic distortion factor
THDR_U1_INST(%)_3P Voltage 1 total harmonic distortion factor
%
TOTAL_P_INST(W)_1P Electric power total value (1st to 50th order)