Security Level - The scanner offers four levels of decode security for UPC/EAN bar codes. Select higher
security levels for lower quality bar codes. There is an inverse relationship between security and decode
speed, so be sure to choose only that level of security necessary for the application.
Level 0 - This default setting allows the scanner to operate fastest, while providing sufficient security in
decoding “in-spec” UPC/EAN bar codes (default).
Level 1 - As bar code quality levels diminish, certain characters become prone to misdecodes before
others (i.e., 1, 2, 7, 8). If the scanner is misdecoding poorly printed bar codes, and the misdecodes are
limited to these characters, select this security level.
Level 2 - If the scanner is misdecoding poorly printed bar codes, and the misdecodes are not limited to
characters 1, 2, 7, and 8, select this security level.
Level 3 - If the scanner is still misdecoding, select this security level. Be advised, selecting this option
is an extreme measure against misdecoding severely out of spec bar codes. Selecting this level of
security can significantly impair the decoding ability of the scanner. If this level of security is necessary,
try to improve the quality of the bar codes.
Supplemental2 - Enables or disables this option. A check in the checkbox indicates that the option is
enabled.
Supplemental5 - Enables or disables this option. A check in the checkbox indicates that the option is
enabled.
Supplemental Mode
No Supplementals - the scanner is presented with a UPC/EAN plus supplemental symbol, the
scanner decodes UPC/EAN and ignores the supplemental characters (default).
Supplemental Always - the scanner only decodes UPC/EAN symbols with supplemental characters,
and ignores symbols without supplementals.
Supplements Auto - the scanner decodes UPC/EAN symbols with supplemental characters
immediately. If the symbol does not have a supplemental, the scanner must decode the bar code the
number of times set via UPC/EAN Supplemental Redundancy before transmitting its data to confirm
that there is no supplemental.
Supplemental Smart - Enables smart supplementals. In this mode the decoder returns the decoded
value of the main block right away if it does not belong to one of the following supplemental types: 378,
379, 977, 978, 979, 414, 419, 434 or 439. If the bar code starts with one of the prefixes it searches the
image more aggressively for a supplemental. Tries to scan the supplemental if it is present. If the
supplemental scanning failed, then the main bar code is returned.
Supplemental 378-379 - Enables (auto-discriminate) supplemental for UPC/EAN codes starting with
378 or 379. Disables reading of supplementals for any other UPC/EAN bar code not starting with 378
or 379. Tries to scan the supplemental if it is present. If the supplemental scanning failed, then the
main bar code is returned.
Supplemental 978-979 - Enables (auto-discriminate) supplemental for UPC/EAN codes starting with
978 or 979. Disables reading of supplementals for another UPC/EAN bar code not starting with 978 or
979. Tries to scan the supplemental if it is present. If the supplemental scanning failed, then the main
bar code is returned.
Supplemental 414-419-434-439 - Enables (auto-discriminate) supplemental for UPC/EAN codes
starting with 414, 419, 434 or 439. Disables reading of supplementals for another UPC/EAN bar code
4 - 16 not starting with 414, 419, 434 or 439. Tries to scan the supplemental if it is present. If the
supplemental scanning failed, then the main bar code is returned.
Supplemental 977 - Enables (auto-discriminate) supplemental for UPC/EAN codes starting with 977.
Disables reading of supplementals for another UPC/EAN bar code not starting with 977. Tries to scan
the supplemental if it is present. If the supplemental scanning failed, then the main bar code is
returned.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra WT6000 Series and is the answer not in the manual?

Zebra WT6000 Series Specifications

General IconGeneral
Storage4 GB Flash
NFCNo
AudioBuilt-in speaker and microphone
Operating Temp-4°F to 122°F (-20°C to 50°C)
Connectivity802.11a/b/g/n
DurabilityIP65
Drop SpecMultiple 4 ft./1.2 m drops to concrete
Operating SystemAndroid™ 5.1 (Lollipop) with Mobility Extensions (Mx)