When setting a max level on intensities, this will be indicated in the
Output Window, by a line above that fixture's intensity.
In the image to the left, fixture 13 and 14 have a max level set of 50%.
Therefore setting the fixture to full takes them to 50%, and setting
them to 50% takes them to 25%.
If you wanted to limit fixture 1 to 50% intensity, you could therefore use the syntax below...
1 @ 5 0 Record Home Max Level
As this is a normal record command, this means that normal Record options apply. The Record Options can be
opened on the internal touchscreen by pressing and holding Record. In most cases when customising Max Levels,
you will need to ensure that the SmartTag option in the Record Options is disabled.
For information on how to do this, see the programming section.
Removing Custom Max Level Values
To remove custom Max Level values, and revert back to the console
defaults, tap Delete Home, and then choose Max Level. This action
can't be undone.
Attribute Settings
Attribute settings allow you to configure how your encoder wheels
behave, for each attribute. The attribute settings can be opened by
pressing and holding the Setup key, and pressing the button of the
attribute you would like to configure. On FLX, you could therefore
press and hold Setup and tap Colour, or on FLX S, you could press
and hold Setup, and tap the Colour tab, at the top of the internal
touchscreen which opens when a fixture with colour parameters is
selected.
Zero 88 - ZerOS - Page 82 of 233 Printed: 23/11/2020 12:50:03 JH