ZyWALL (ZLD) CLI Reference Guide
207
CHAPTER 32
System
This chapter provides information on the system screens.
32.1 System Overview
The system screens can help you configure general ZyWALL information, the system time and
the console port connection speed for a terminal emulation program. The screens also allow
you to configure DNS settings and determine which services/protocols can access which
ZyWALL zones (if any) from which computers.
32.2 Host Name Commands
The following table describes the commands available for the hostname and domain name.
You must use the
configure terminal command to enter the configuration mode before
you can use these commands.
32.3 Time and Date
For effective scheduling and logging, the ZyWALL system time must be accurate. The
ZyWALL’s Real Time Chip (RTC) keeps track of the time and date. There is also a software
mechanism to set the time manually or get the current time and date from an external server.
Table 123 Command Summary: Host Name
COMMAND DESCRIPTION
[no] domainname domain_name Sets the domain name. The
no command removes the domain
name.
domain_name: This name can be up to 254 alphanumeric
characters long. Spaces are not allowed, but dashes “-” and
underscores “_” are accepted.
[no] hostname hostname Sets a descriptive name to identify your ZyWALL. The
no
command removes the host name.
show fqdn Displays the fully qualified domain name.

Table of Contents