Additional Information
Basic Commands
»
Basic Get commands to the EDGE panel will receive a response of Basic Report Value 0
»
Basic Set commands to the EDGE panel are ignored
Group Identier
»
Only Group 1 is supported
»
Max number of devices per group: 1
Associations
»
Associations can be set by controllers with the ASSOCIATION_SET command
»
Associations supported commands:
»
COMMAND_CLASS_DEVICE_RESET_LOCALLY
»
DEVICE_RESET_LOCALLY_NOTIFICATION
NOTE: Associations are not controlled/supported through the EDGE UI.
S2
»
Supported Command Classes and Security Levels
NOTE: EDGE minimum required security level is none.
Command Class
Version
Number
COMMAND_CLASS_ZWAVEPLUS_INFO 2
COMMAND_CLASS_MANUFACTURER_SPECIFIC 1
COMMAND_CLASS_SECURITY 1
COMMAND_CLASS_SECURITY_2 1
COMMAND_CLASS_INCLUSION_CONTROLLER 1
COMMAND_CLASS_TRANSPORT_SERVICE_V2 2
COMMAND_CLASS_DEVICE_RESET_LOCALLY 1
COMMAND_CLASS_POWERLEVEL 1
COMMAND_CLASS_CRC_16_ENCAP 1
COMMAND_CLASS_ASSOCIATION_V2 2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 3
COMMAND_CLASS_SUPERVISION 1
Controller Replication
Controller replication is not supported through the panel User Interface. Please consult your backend provider if the
replication option is available through the dealer portal.