A-2
A.2. LEL Sensor Types
There are several LEL sensor types available for the monitor. The following table shows the benefits
of each sensor and the combustible gases it will detect:
LEL Sensor Benefit Gas Detected
Certification
Gas Group
Division/Zone
Standard Filtered
P/N: 66725
Detects most combusti-
ble gases
C1 - C8 Hydrocarbons
Includes but not limited to:
Methane, Ethane, Pro-
pane, Butane, Pentane,
Hexane, Heptane, Octane
& Hydrogen
IIC
A,B,C & D
Class I, Div 1,2
Zones 1,2
Enhanced Filtered
P/N: 64825
Enhanced H2S and Sili-
cone poisoning resistance
C1 - C6 Hydrocarbons
Includes but not limited to:
Methane, Ethane, Pro-
pane, Butane, Pentane,
Hexane & Hydrogen
IIC
A,B,C & D
Class I, Div 1,2
Zones 1,2
Low Power
P/N: 66750
Improved battery life
C1 - C5 Hydrocarbons
Includes but not limited to:
Methane, Ethane, Pro-
pane, Butane, Pentane
IIB
C & D
Class I, Div 1,2
Zones 0,1,2
Infrared P/N: 66761
Improved
battery life,
poison/silicone/contami-
nation resistant,
Able to detect methane in
oxygen depleted atmo-
spheres
Methane only
Will not detect Hydrogen
(H
2
)
IIC
ATEX/IECEx
only
Zone 1
ATEX/IECEx
only
WARNING: ONLY THE STANDARD FILTERED AND THE ENHANCED FILTERED
SENSORS ARE INTERCHANGABLE.

Table of Contents

Other manuals for 3M GMI PS200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3M GMI PS200 Series and is the answer not in the manual?

3M GMI PS200 Series Specifications

General IconGeneral
Brand3M
ModelGMI PS200 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals