EasyManua.ls Logo

A&D GF-30K - 14 Programmable Unit

A&D GF-30K
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
74
14. Programmable Unit
This is a programmable unit conversion function. It multiplies the weighing data in kilograms by an
arbitrary coefficient set in "Programmable unit (
mlt
)" of the function table and displays the result.
The coefficient must be within the range between the minimum and maximum shown below. If the
coefficient set is beyond the range, an error is displayed and the balance returns to the coefficient
setting mode, prompting to enter an appropriate value. A coefficient of 1 was set at the factory.
Model Minimum coefficient Maximum coefficient
GX-8K GX-10K
GF-8K GF-10K
100000
GX-8K2 GX-12K GX-20K GX-30K
GF-8K2 GF-12K GF-20K GF-30K
10000
GX-32K
GF-32K
0.000001
1000
Operation
Step 1 Press and hold the SAMPLE key until ba5fnc of the function table is displayed,
then release the key.
Step 2 Press the SAMPLE key several times to display mlt .
Step 3 Press the PRINT key to enter the mode to confirm or set the coefficient.
Confirming the coefficient
Step 4 The current coefficient is displayed with the first digit blinking.
When it is not to be changed, press the CAL key and go to step 6.
When it is to be changed, press the RE-ZERO key and go to step 5.
Setting the coefficient
Step 5 Set the coefficient using the following keys.
SAMPLE key
....
To select a digit to change the value.
The selected digit blinks.
RE-ZERO key
...
To change the value.
MODE key
.......
To change the decimal point position.
Each time the switch is pressed, the
decimal point position changes as follows:
PRINT key
........
To store the new coefficient, display end
and go to step 6.
CAL key
...........
To cancel the new coefficient and go to step 6.
Quitting the operation
Step 6 The balance displays Unit . Press the CAL key to exit the programmable-unit
function and return to the weighing mode.
Using the function
Press the MODE key to select the programmable-unit (no display on the unit section).
Perform weighing as described in "6-1. Basic Operation (Gram Mode)". After weighing, the
balance displays the result (weighing data in kilograms
x
coefficient).
Store

Table of Contents