Hardware Installation
Figure 34 Installing AC/DC Unit 115-230 V
1. If not already done, mount four captive nuts (A) (see Section 4.4 on page
41 ) according to the number positions shown, see Figure 37.
2. Slide the AC/DC unit between the shelves until it reaches a fixed position,
see Figure 37. Some use of force may be required to firmly fix the unit
between the shelves. In this position it is possible to pull the unit forwards
to allow easier cable connection work.
3. Use the four screws (C) supplied with the mounting kit to fasten the AC/DC
unit to the captive nuts in the cabinet. Do not tighten the screws, as they
need to be opened again when connecting cables to the AC/DC unit.
4. Connection to the mains supply and protective earthing (D) in the building
shall be carried out by a service person. The manufacturers instructions
manual must be followed, see Figure 38.
5. Fasten the warning label, energy hazard (SVB 131 75) below the circuit
breakers on the front of the AC/DC unit, see Figure 38 and see Figure 58.