AMT/PTD/PBX/0020/2/4/EN 01/2007 Page 173
9.7 Registration and putting in service
9.7.1 Declaring a mobile in the PBX
A mobile must be created for each subscriber.
MENU 1.8.3.1 (single-company) or 1.9.3.1 (multi-company)
1 Enter the directory number to be assigned to the mobile.
2 Reference cell, not used in DECT service (do not fill in).
3 Enter the backup set to which the mobile’s calls will be directed when it is out of service or
not located (out of coverage area range). If no backup set is declared, external calls will be
forwarded to the attendant console, and internal calls will receive the busy tone.
4 In the "TELEPHONY MANAGEMENT" menu under "EXTENSION DATA" it is possible to
modify the subscriber’s restrictions and features.
Menu 1.1.1 Extension characteristics
Enter the information corresponding the user’s profile and restrictions.
CREATE MOBILE
-----------------------
DIRECTORY NUMBER 7542.
COMPANY AASTRA
DEPARTMENT 115..
WIRELESS TYPE DECT
REFERENCE CELL .......
DIRECTORY OF EMERGENCY EXTENSIONS
.......
DECT MOBILE EXTENSION
SUBSCR. STATUS IN SERVICE
DIRECTORY NUMBER 7542.
DID DIRECTORY NUMBER PLAN 1 ......
EXTENSION NAME P.DUPOND
COMPANY AASTRA
DEPARTMENT 115..
REFERENCE CELL .......
INTEGRATED VOICE BOX (IVB) NO
SERVICE BEARER SPEECH
DIRECTORY OF EMERGENCY EXTENSIONS 7778.
DAY CATEGORY INTERNATIO.
NIGHT CATEGORY INTERNATIO.
DAY TL CLASS 48.....
Etc.