ACH580 Installation, Operation and Maintenance Manual 13
ACH580-01 Installation
IP21 (UL (NEMA) Type 1)
4. Remove the front cover: Remove the fastening screws (4a) with a T20 To
rx
screwdriver and
lift the cover from the bottom upwards (4b) and then to
the
top side
(4c).
5. Attach the cable box to the drive frame.
6. Tighten the box nuts.
7. Slide the box cover from the bottom (7a) and tighten the retaining screws (7b).
8. Put the tabs at the top of the front cover in their counterparts on the housing
and
then
press at the bottom (8a) and tighten the retaining screws (8b).
IP21 (UL (NEMA) Type 1), IP55 (UL (NEMA) Type 12)
9. Position the drive onto the four bolts on the wall. Lift the drive with another person
or
with a
lifting device as it is heavy. Tighten the bolts in the wall securely.
10. Tighten the two remaining bolts securely.
Note: Install the hood on UL (NEMA) Type 12 drives after you have installed the
drive electrically and reinstalled covers.
4 5
6
4a
4b
4c
3×M5
7
8
7a
7b
7b
8a
8b
9
10
9a
9b
9b
×2
×2