time. The pulse voltage can almost double at the motor terminals, depending on the
attenuation and reflection properties of the motor cable and the terminals. This can cause
additional stress on the motor and motor cable insulation.
Modern variable speed drives with their fast rising voltage pulses and high switching
frequencies can generate current pulses that flow through the motor bearings. This can
gradually erode the bearing races and rolling elements.
du/dt filters protect motor insulation system and reduce bearing currents. Common mode
filters mainly reduce bearing currents. Insulated N-end (non-drive end) bearings protect the
motor bearings.
Requirements table
These tables show how to select the motor insulation system and when a drive du/dt and
common mode filters and insulated N-end (non-drive end) motor bearings are required.
Ignoring the requirements or improper installation may shorten motor life or damage the
motor bearings and voids the warranty.
Guidelines for planning the electrical installation 73

Table of Contents

Other manuals for ABB ACQ580-34

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACQ580-34 and is the answer not in the manual?

ABB ACQ580-34 Specifications

General IconGeneral
Product nameABB ACQ580-34
Product typeControl Unit
Number of phases3
Mounting typeWall-mounted
Built-in EMC filterYes
Brake chopperOptional
Output frequency0-500 Hz
Rated supply voltage380-480 V
Control methodvector control
I/ODigital and analog inputs/outputs
CommunicationModbus RTU
ApplicationPumps, Fans
Enclosure classIP55