6. Twist the cable shields of the input cables into bundles and connect them and any
separate ground conductors or cables to the drive module ground terminal or to the
cabinet PE busbar.
7. Connect the phase conductors of the input cables to terminals L1/U1, L2/V1 and L3/W1
of the drive module. For the tightening torques, see the technical data.
Connecting the control cables to the integrated control unit
See chapter Control unit (page 111) for the default I/O connections of the drive control
program. The default I/O connections can be different with some hardware options, see the
circuit diagrams delivered with the drive for the actual wiring.
1. Ground the outer control cable shields 360 degrees at the cabinet entry plate
(recommendation).
2. Remove the middle front cover of the drive module.
3. Attach the option modules if not attached already.
4. Remove the cover plate from the control cable entry plate and put the rubber grommet
in its place. Put the control cables through the grommet.
Note: Drive module with IP20 shrouds (option +B051): If you route the control cables
from top or bottom instead of front or side, you need to make holes for the entry plates
to the clear plastic shrouds.
2
Combi screw
M4×8 Torx T20
2 N·m
4
4
IP20 shrouds (option +B051) included in the drawing
104 Electrical installation