462 Fieldbus control through a fieldbus adapter
System overview
The drive can be connected to an external control system through a serial
communication link using a fieldbus adapter. The fieldbus adapter can be installed
into any free drive slot.
The drive can be set to receive all of its control information through the fieldbus
interface, or the control can be distributed between the fieldbus interface and other
available sources such as digital and analog inputs.
Data Flow
Process I/O (cyclic)
Process I/O (cyclic) or
Service messages (acyclic)
Control word (CW)
References
Fieldbus
controller
Parameter R/W requests/responses
Status word (SW)
Actual values
Fieldbus
Other
devices
Drive
Type Fxxx fieldbus
adapter installed on
drive

Table of Contents

Related product manuals