364 Appendix A – PROFIdrive parameters and I&M records of PROFINET IO
PROFIdrive parameters
Par. no. R/W
1)
Data type Description
915 R/W Array [12]
Unsigned16
Assignment PZD1 to PZD12 in PPO-
write
916 R/W Array [12]
Unsigned16
Assignment PZD1 to PZD12 in PPO-
read
919 R Octet String4 Device system number
922 R Unsigned16 Telegram selection
923 R Array [n]
Unsigned16
List of all parameters for signals.
Mandatory if process data
normalization is used and/or
parameters 915 and 916 are
implemented.
Signal no. and name Type
1 – Control word 1
(STW1)
Unsigned16
2 – Status word 1
(ZSW1)
Unsigned16
3 – Control word 2
(STW2)
Unsigned16
4 – Status word 2
(ZSW2)
Unsigned16
5 – Speed set point A
(NSOLL_A)
Signed16
6 – Speed actual value
A (NIST_A)
Signed16
7 – Speed set point B
(NSOLL_B)
Signed32
8 – Speed actual value
B (NIST_B)
Signed32
27 Position set point
A (XSOLL_A)
Signed32
28 – Position actual
value A (XIST_A)
Signed32