Figure 4-9: Station Setup screen 
5.  Change any other settings in the Station Setup tab as necessary. Leave PCCU open to the 
Station Setup tab. 
 
Additional fields in WinCCU 
uniquely identify the meter, including fields for the 
lease holder, producer, operator, and buyer. Edit these fields on the host computer in the ID 
manager, not on the RMC.
 
4.3.2  Change the LCD display 
The factory configuration has a default date and time display format. The display configuration is 
backward-compatible with the XSeriesG4 and XSeriesG5.  
To change the display to preferred settings on the Station Setup tab: 
1.  Scroll down to the LCD Display Date/Time Format (Figure 4-10
). 
Figure 4-10: LCD display date and time format 
2.  Select a Date/Time Format (mmddyy or yymmdd) from the drop-down list. 
3.  Select a Date Separator (slash, dash, or period). 
4.  Select a Time Separator (colon or period). 
5.  Click Send to save the station settings. 
 
4.4  Configure serial communications 
4.4.1  Configure serial communication ports 
Configure COM 1 and COM 2 communication ports to connect one or more peripheral serial devices. 
These ports are software-configurable to support RS-232, RS-422, and RS-485. 
To configure the port: 
1.  Verify that the power LED on the COM module is on (green).