42/23-81 EN Rev. 4 System Manual SCK Gas Sampling System 73
Danger Where / in what situa-
tion does the danger
arise?
Preventive action
Danger due to cur-
rent-carrying parts
When working on elec-
tric components
Only specialized electrical
personnel may work on the
electric system.
Disconnect the gas sam-
pling system from the pow-
er supply before opening
the connection and terminal
box.
Observe national regula-
tions pertaining to electrical
equipment.
Risk of burning due
to hot surfaces
The following compo-
nents are very hot during
and after operation of
the gas sampling sys-
tem:
the cooling module
the heated sample
gas lines
the connection box
for the heated sample
gas line on the retrac-
tor
the heated sampling
filter
the entire gas sam-
pling probe
the metal structure of
the retractor
the shutter of the duct
opening
Do not touch these compo-
nents during and after op-
eration.
Do not touch these compo-
nents until they have
cooled down to less than
50 °C.
If it is unavoidable to touch
hot components, wear a
face mask against heat,
heat-proof gloves and pro-
tective welder's clothing.
Risk of burning due
to falling or spalling
material.
After the probe moves
out of the rotary kiln, hot
material may fall or spall
off the probe.
Never enter the danger
area around the retractor
during operation.
Do not approach the re-
tracted probe until it has
cooled down.
If it is unavoidable to ap-
proach the hot probe, wear
a face mask against heat,
heat-proof gloves and pro-
tective welder's clothing.