EasyManua.ls Logo

ABB TPS48-H33 - Page 62

ABB TPS48-H33
130 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / 4 Product description / TPS44-H.. - TPS52-H..
5
Operation and service
Page 32 /
99
© Copyright 2016 ABB. All rights reserved.
HZTL4037_EN
Revision A
August 2016
5.2.1 Service work every 24 … 48 hours
Pipes
Check all the inlet and outlet pipes of the turbocharger for leaks.
Operating data
CAUTION
Unknown operational changes
Impairment to the degree of a possible operating failure can be the conse-
quence.
Get an ABB Turbocharging Service Station to clarify unknown causes.
Monitoring the engine's operating data makes it possible to draw conclusions about the oper-
ating behaviour of the turbocharger.
The following operating data and measured values must be entered every 24 … 48 hours
in the engine logbook of the enginebuilder.
Performance and speed of the engine
Air intake temperature
Charging pressure
Pressure loss in the charge air cooler
Lubricating oil pressure and lubricating oil temperature
If present:
Speed of the turbocharger
Air temperature after the compressor and after the charge-air cooler
Exhaust gas temperature before and after the turbine
Pressure loss in the filter silencer.
In case of different values, determine the cause.
5.2.2 Service work at 100 hours after commissioning
Clean or replace the oil filter located in the supply pipe to the turbocharger while the en-
gine is stopped.
5.2.3 Service work according to instructions of enginebuilder
Clean or replace the oil filter located in the supply pipe to the turbocharger while the en-
gine is stopped.