EasyManua.ls Logo

ABB TPS48-H33 - Malfunctions During Operation; Table 16 Malfunctions During Operation - Lubricating Oil Pressure too Low; Table 17 Malfunctions During Operation - Speed Reduces; Table 18 Malfunctions During Operation - Speed Increases

ABB TPS48-H33
130 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / 4 Product description / TPS44-H.. - TPS52-H..
8
Eliminating malfunctions
Page 52 /
99
© Copyright 2016 ABB. All rights reserved.
HZTL4037_EN
Revision A
August 2016
8.2 Malfunctions during operation
Lubricating oil pressure too low
Possible causes
Remedy
Engine Oil filter heavily contaminated Clean
Oil pump in lubricating system defective Check/replace
Manometer displays incorrectly Replace manometer
Turbocharger Axial clearance of the rotor excessive Contact ABB Turbocharging Service Station
Table 16: Malfunctions during operation Lubricating oil pressure too low
Speed reduces
Possible causes
Remedy
Engine
Defect on the connected cylinders in
pulse charging
Contact enginebuilder
Turbocharger Turbine and/or nozzle ring severely con-
taminated
Clean (see chapter Periodic maintenance
work [➙ 39])
Rotor components or bearing damaged Contact ABB Turbocharging Service Station
Pipes Defects, such as leaks, in the exhaust
gas pipes or charge air ducts
Repair
Table 17: Malfunctions during operation Speed reduces
Speed increases
Possible causes
Remedy
Turbocharger Light to medium contamination of the
turbine and/or nozzle ring (with 4-stroke
application)
Clean (see chapter Periodic maintenance
work [➙ 39]) or contact an ABB Turbocharg-
ing Service Station
Table 18: Malfunctions during operation Speed increases

Table of Contents

Related product manuals