Operation Manual / 4 Product description / TPS44-H.. - TPS52-H..
Page 52 /
© Copyright 2016 ABB. All rights reserved.
8.2 Malfunctions during operation
Lubricating oil pressure too low
Engine Oil filter heavily contaminated Clean
Oil pump in lubricating system defective Check/replace
Manometer displays incorrectly Replace manometer
Turbocharger Axial clearance of the rotor excessive Contact ABB Turbocharging Service Station
Table 16: Malfunctions during operation – Lubricating oil pressure too low
Defect on the connected cylinders in
pulse charging
Turbocharger Turbine and/or nozzle ring severely con-
taminated
Clean (see chapter Periodic maintenance
work [➙ 39])
Rotor components or bearing damaged Contact ABB Turbocharging Service Station
Pipes Defects, such as leaks, in the exhaust
gas pipes or charge air ducts
Repair
Table 17: Malfunctions during operation – Speed reduces
Turbocharger Light to medium contamination of the
turbine and/or nozzle ring (with 4-stroke
application)
Clean (see chapter Periodic maintenance
work [➙ 39]) or contact an ABB Turbocharg-
ing Service Station
Table 18: Malfunctions during operation – Speed increases