Motor Management
Control function
Reverse lockout time
1
YD changeover mode
2
YD starting time
2
Time limit actuator
3
Fault output
Checkback
Inching DI start input
Auto ctrl mode
Invert ctrl inputs
Multifunction inputs
Enable custom logic
Limit number of starts
Extended
Resisitive load
Number of phases
Warnlevel oper.hours
Warnlev standstill h
1) Only for control function REV
2) Only for control function YD
3) Only for control function Actuator
Loc1 start bus cyc.
Loc1 stop bus cyc.
Loc1 start LCD
Loc1 stop LCD
Loc1 start bus acyc.
Loc1 stop bus acyc.
Loc1 start DI
Loc1 stop DI
Auto ctrl mode
Auto start bus cyc.
Auto stop bus cyc.
Auto start LCD
Auto stop LCD
Auto start bus acyc.
Auto stop bus acyc.
Auto start DI
Auto stop DI
Extended
Emergency start
Fault auto reset
Custom app parameter
Param to PV 1
...
Param to PV5
Check-Back Time
Auxiliary inputs
Auxiliary inputs
Aux inp 1 ack mode
Aux inp 1 reaction
Aux inp 1 delay
Aux inp 1 message L1
Aux inp 1 message L2
(Same repeats for Aux
2 ... 6)
Loc2 start bus cyc.
Loc2 stop bus cyc.
Loc2 start LCD
Loc2 stop LCD
Loc2 start bus acyc.
Loc2 stop bus acyc.
Loc2 start DI
Loc2 stop DI
Multifunction inputs
Multifunction 0
Multifunction 1
Multifunction 2
Multif. 0 delay
Multif. 1 delay
Multif. 2 delay
Multif. 0 autoreset
Multif. 1 autoreset
Multif. 2 autoreset
Multif. 0 fault text L1/2
Multif. 1 fault text L1/2
Multif. 2 fault text L1/2
Invert ctrl inputs
Invert DI start inp.
Invert DI stop inp.
Limit num of starts
Num starts allowed
Num starts window
Num starts pause
Num starts overrun
Num starts prewarn
Motor Management Parameters
Within this submenu all motor management related parameters can be configured.
The diagram below shows the organisation of the different parameter masks in the menu tree.
The parameters are described in details in the section "Parameters and Data Structures on a Fieldbus->Parameter
Organisation-> Motor Management Parameters". A description of the parameters of the menu entry "Auxiliary
inputs" can be found in the section "Parameters and Data-Structures on a Fieldbus->Parameter Organization->
Function Block Related Parameters".
104