7474 75|
15. Technical data
Voice dialler
Receiver
8 Tel or VoIP/SIP ID
DTMF detection VoIP/SIP
Acknowledgement
RFC 2833
Codec VoIP/SIP
PCM G711 A law (RTP AV Prole 8)
ITU-T G.711 PCM A-Law audio 64kbit/s
Reference RFC 3551
SMS
Receiver
8
PSTN SMS protocol TAP 8N1, TAP 7E1, UCP 8N1, UCP 7E1, ETSI Protocol 1
Email
Receiver 8
Remote control by telephone Yes
ATS Alarm transmission system
Categories and classications
ATS (Alarm Transmission System)
categories, SPT (Supervised Premises
Transceiver) classication
The alarm panel contains an integrated SP2 (ATS2)
communicator to full the requirements of EN50131 for security
grade 2.
The alarm transmission system is compliant with
EN50136-1:2012 as an SP2 (ATS2) communicator.
The alarm panel supports options A, B and C for grade 2 as
given in Table 10 in EN50131-1:2006+A1:2009.
Classication of transmission time D2 -> SP2
Transmission time, maximum
values
M2 -> SP2
Classication of notication time T2 -> SP2
Classication of availability
A0 (no requirement)-> SP2 (optional)
There is no method for achieving compliance with EN 50136-
1:2012, 6.7.3 (non-availability of the alarm transmission system)
because A0, no requirement.
Security to prevent removal
S0 (no measures) -> SP2 (optional)
There is no method for achieving compliance with
EN50136-1:2012, 6.7.2 (redundancy) because S0, no measures.
Information security
I0 (no measures) -> SP2 (optional)
There is no method for achieving compliance with
EN50136-1:2012, 6.8.3 (information security) because I0,
nomeasures.