EVO 150 Controller
36
Web Server Subnet Mask – 4
th
Octet
9 3 0
This parameter sets the 4
th
Octet of the controller boards Web Serve
Subnet Mask. The default value is 0.
Range: 0 to 255
Note: This is not the subnet mask for the fieldbus, see page 103.
Web Server Gateway – 1
st
Octet
9 4 2 5 5
This parameter sets the 1
st
Octet of the controller boards Web Serve
Gateway. The default value is 192.
Range: 0 to 255
Note: This is not the gateway for the fieldbus, see page 103.
Web Server Gateway – 2
nd
Octet
9 5 2 5 5
This parameter sets the 2
nd
Octet of the controller boards Web Serve
Gateway. The default value is 168.
Range: 0 to 255
Note: This is not the gateway for the fieldbus, see page 103.
Web Server Gateway – 3
rd
Octet
9 6 2 5 5
This parameter sets the 3
rd
Octet of the controller boards Web Serve
Gateway. The default value is 0.
Range: 0 to 255
Note: This is not the gateway for the fieldbus, see page 103.
Web Server Gateway – 4
th
Octet
9 7 0
This parameter sets the 4
th
Octet of the controller boards Web Serve
Gateway. The default value is 1.
Range: 0 to 255
Note: This is not the gateway for the fieldbus, see page 103.
Centerline Mode
9 8 0
This is the default setting. Standard centerline guiding with two edge
detectors.
9 8 1
Centerline guiding with one edge detector. Detector
or Detector B can
be used.
9 8 2
This setting is not yet implemented.
9 8 3
Super Centerline mode. Centerline guiding of a narrow web over the
entire range of two edge detectors.