EVO 150 Controller
7
6. PLC I/O Board (optional)
Links the EVO 150
system with a remote PLC
Opto-isolated digital I/O provides control of operating mode and monitoring of end-of-
travel status and other indicators
7. Serial I/O Board (optional)
Links the EVO 150
controller with a remote station and/or digital line guide
8. Fieldbus Interface (optional)
Links the EVO 150
system with a remote PLC or computer through a fieldbus network
Compatible with many fieldbus protocols, including Ethernet/IP, PROFINET, Modbus
TCP/IP
Provides control of operating mode, guide point position, and other functions
Permits monitoring of actuator position, web position, and other status indicators
Product Specifications:
Enclosure size (H x W x D): 5.50” [140mm] x 8.50” [216mm] x 3.38” [86mm]
Power requirements: 24 VDC +/-10% 4 Amperes maximum from isolated source
Operating environment:
Maximum ambient temperature 120 deg F [48.9 deg C]
Humidity 0-90% non-condensing
Pollution degree 2