4 1 1
The range of Analog Input 1 is 0 to +5 volts.
4 1 2
The range of Analog Input 1 is 0 to +10 volts.
4 1 3
The range of Analog Input 1 is -10 to +10 volts.
Analog Input 2 Range (actuator position signal)
4 2 0
If parameter 2 is set to 1, then the range of Analog Input 2 is
automatically set to 0 to +5 volts. If parameter 2 is not set to 1, then
Analog Input 2 is off. This is the default setting.
4 2 1
The range of Analog Input 2 is 0 to +5 volts.
4 2 2
The range of Analog Input 2 is 0 to +10 volts.
4 2 3
The range of Analog Input 2 is -10 to +10 volts.
Analog Input 1 Scale Factor (coarse)
4 3 a a a b b
This parameter sets the scale factor for Analog Input 1. Use this
parameter to adjust digits aaa. Use parameter 44 to adjust digits bb.
Range: 0 to 25599
The default value is 100.
Analog Input 1 Scale Factor (fine)
4 4 a a a b b
This parameter sets the scale factor for Analog Input 1. Use this
parameter to adjust digits bb. Use parameter 43 to adjust digits aaa.
Range: 0 to 25599
The default value is 100.
Analog Input 2 Scale Factor (coarse)
4 5 a a a b b
This parameter sets the scale factor for Analog Input 2. Use this
parameter to adjust digits aaa. Use parameter 46 to adjust digits bb.
Range: 0 to 25599
The default value is 100.
Analog Input 2 Scale Factor (fine)
4 6 a a a b b
This parameter sets the scale factor for Analog Input 2. Use this
parameter to adjust digits bb. Use parameter 45 to adjust digits aaa.
Range: 0 to 25599
The default value is 100.