Sensor B Transducer Orientation
This parameter reverses the order of the transducer beams in Sensor B.
7 5 0
This is the default setting. Beam 1 is located at the end of the
transducer closest to the pigtail wiring.
7 5 1
Beam 1 is located at the end of the transducer farthest from the pigtail
wiring.
Sensor A Reduced Length
7 6 2
This parameter is used to reduce the sensing area of WideArray senso
r
A
by establishing the number of active beams. As the value of this
parameter is lowered the low-numbered beams will be deactivated first,
beginning with beam 1. The minimum value for WideArray sensors is 4.
The minimum value for PointSource sensors is 2. The maximum value is
determined by parameter 24. The default value is 2.
Range: 2 to 128
Note: Parameter 24 must always be set to the actual full length of sensor A.
Sensor B Reduced Length
7 7 2
This parameter is used to reduce the sensing area of WideArray senso
r
B by establishing the number of active beams. As the value of this
parameter is lowered the low-numbered beams will be deactivated first,
beginning with beam 1. The minimum value for WideArray sensors is 4.
The minimum value for PointSource sensors is 2. The maximum value is
determined by parameter 25. The default value is 2.
Range: 2 to 128
Note: Parameter 25 must always be set to the actual full length of sensor B.
Fieldbus Swap Bytes
This parameter swaps the high and low bytes of all fieldbu
s input and output data words.
7 8 0
This is the default setting. The data bytes are not swapped.
7 8 1
The data bytes are swapped.