SECTION II
FEATURES
A. Dependable Microprocessor Solid State Integrated Circuitry To eliminate as many moving parts as
possible.
B. Sensor Activated Fire Extinguishing (S.A.F.E.) System A feature, which continually monitors the
basket (tumbler) for fires. In the event of a fire, a water supply to the basket (tumbler) will suppress the fire.
The Phase 7 dual microprocessor controller (DMC) computer will also notify the user that a fire has taken
place.
C. Program Changes are Easily Made at the Keyboard (Touch Pad)Actual programs are viewed at the
liquid crystal display (L.C.D.) startup or verification.
D. Temperature Selections Accommodates three (3) temperature settings:HI ,MED , and
“LO” , each programmable to a drying temperature between 100°F (38°C) and 190°F (8C) for radial
airflow or 100°F (38°C) and 150°F (66°C) for axial airflow.
E. Cool Down – Cool down lowers the temperature in the basket (tumbler) to make the material cool enough
to handle.
F. L.C.D. – Informs user of cycle status and programs; displays important diagnostic and fault codes.
G. Wrinkle Guard Program Helps keep items wrinkle-free when they are not removed from the dryer
promptly at the end of the drying and cooling cycles.
H. Diagnostics Major circuits, including the door switch(es), microprocessor temperature sensor, heat output
circuits, and more are individually monitored, allowing for precise messages of your failure.
I. Audio Alert SignalThe tone will sound at the end of a complete drying cycle at a 1-second rate for the
duration programmed. It will also sound for any fault conditions at a quarter-second rate for 4-beeps.
Finally, there is a 3-beep warning at the beginning of every Wrinkle Guard On Cycle, and a continuous rapid
pulse is used for the entire duration of S.A.F.E. system activation.
J. Temperature Conversion Status Temperature-related programs can be set in either Fahrenheit (°F) or
Celsius (°C). ALL temperatures will automatically convert to the corresponding values (+/- 1°) when
changes are made.
K. High Temperature Protection – If the Phase 7 DMC (computer) senses that the temperature in the basket
(tumbler) has exceeded 180°F (82°C) for axial airflow or 210°F (98°C) for radial airflow, it will end the drying
cycle, and a fault code will be displayed indicating an overheating problem.
L. RPMThe Phase 7 DMC (computer) monitors the speed of the basket (tumbler) rotation.
M. Clean Lint This feature notifies the user when the lint access should be cleaned.
N. Language Selection – The Phase 7 DMC (computer) has the ability to display English and Japanese.