ADTECH9 Series CNC Maintenance Manual
- 156 -
Authority : Super Admin
Default : Standard Pluse Mode
Effective time : Instant
Note : To set the servo spindle quasi-stop control output port number (Note: This
parameter is used when the servo spindle is configured for this axis)
051 X servo pulse control output port number
Y servo pulse control output port number
Z servo pulse control output port number
A servo pulse control output port number
B servo pulse control output port number
C servo pulse control output port number
Range : 0~8888
Unit :
Authority : Super Admin
Default : Standard Pluse Mode
Effective time : Instant
Note : To set the control output port number when servo spindle simulates and
switch with the pulse mode (Note: This parameter is used when the servo
spindle is configured for this axis)
052 X servo rigid tapping mode output port
Y servo rigid tapping mode output port
Z servo rigid tapping mode output port
A servo rigid tapping mode output port
B servo rigid tapping mode output port
C servo rigid tapping mode output port
Range : 0~8888
Unit :
Authority : Super Admin
Default : Standard Pluse Mode
Effective time : Instant
Note : To set the control output port number when the servo spindle is switched