ADTECH9 Series CNC Maintenance Manual
- 157 -
to the rigid tapping mode (Note: This parameter is used when the servo
spindle is configured for this axis)
053 X servo spindle ready input port
Y servo spindle ready input port
Z servo spindle ready input port
A servo spindle ready input port
B servo spindle ready input port
C servo spindle ready input port
Range : 0~8888
Unit :
Authority : Super Admin
Default : Standard Pluse Mode
Effective time : Instant
Note : To set the input detection port prepared by the servo enable for servo
spindle detection (Note: This parameter is used when the servo spindle is
configured for this axis)
054 X servo spindle quasi-stop in-position input port
Y servo spindle quasi-stop in-position input port
Z servo spindle quasi-stop in-position input port
A servo spindle quasi-stop in-position input port
B servo spindle quasi-stop in-position input port
C servo spindle quasi-stop in-position input port
Range : 0~8888
Unit :
Authority : Super Admin
Default : Standard Pluse Mode
Effective time : Instant
Note : To set the servo quasi-stop in-position input detection port for the servo
spindle detection (Note: This parameter is used when the servo spindle is
configured for this axis)