ADTECH9 Series CNC Maintenance Manual
- 158 -
055 X servo spindle zero speed in-position input port
Y servo spindle zero speed in-position input port
Z servo spindle zero speed in-position input port
A servo spindle zero speed in-position input port
B servo spindle zero speed in-position input port
C servo spindle zero speed in-position input port
Range : 0~8888
Unit :
Authority : Super Admin
Default : Standard Pluse Mode
Effective time : Instant
Note : To set the zero speed in-position input detection port after servo stop
during servo spindle detection (Note: This parameter is used when the
servo spindle is configured for this axis)
056 X servo spindle speed reaches the input port
Y servo spindle speed reaches the input port
Z servo spindle speed reaches the input port
A servo spindle speed reaches the input port
B servo spindle speed reaches the input port
C servo spindle speed reaches the input port
Range : 0~8888
Unit :
Authority : Super Admin
Default : Standard Pluse Mode
Effective time : Instant
Note : To set the input detection port when the servo speed reaches during servo
spindle detection (Note: This parameter is used when the servo spindle is
configured for this axis)
10.4
Management parameter (P3.)
001 Select administrator mode

Table of Contents

Other manuals for Adtech CNC9650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Adtech CNC9650 and is the answer not in the manual?

Adtech CNC9650 Specifications

General IconGeneral
BrandAdtech
ModelCNC9650
CategoryControl Systems
LanguageEnglish

Related product manuals