ADTECH9 Series CNC Maintenance Manual
- 164 -
additional panel is used. However, if no additional panel is used, this
parameter must be enabled, or else the axis motion can’t be controlled
through the key.
022 Additional panel enable
Range : OFF FCNC4M FDK4A FCNC900V FCNC6D
Unit : None
Authority : Super user
Default : OFF/0
Effective time : Instant
Note : Used to configure whether NC uses additional panel, which must be ADT
matching additional panel, or compatible with the interface of same
protocol.
If additional panel is used, the system testing info enable must be
deactivated (P3.20).
023 M code macro program selection
Range : MFUNC User-Def
Unit : None
Authority : Super user
Default : MFUNC
Effective time : Restart
Note : Used to configure M code macro program of the system, MFUNC uses the
default M code macro program, and User-Def uses user-defined
M_FUNC.NC.
024 T macro program selection
Range : TFUNC User-Def
Unit : None
Authority : Super user
Default : TFUNC
Effective time : Instant