42
Regardless of the BDSI (Between Dive Surface Interval) time set, access to Log
Mode can be gained by depressing the A button for 2 seconds while viewing the
Free Surface Main or Watch Default Time screen.
Upon entering Log Mode, the most recent dive’s Log 1 screen will be displayed.
• Depressing the A button for 2 seconds will bypass other Log screens and
advance to History Mode.
• Pressing and releasing the A button momentarily (< 2 seconds) will access
that dive's Log 2 screen, then again that dive's Log 3 screen.
• Depressing the S button while viewing a Log 1 or 2 screen will scroll through
the previous dives' Log 1 or 2 screens at a rate of 8 per second.
Pressing and releasing the S button momentarily and repeatedly (< 2
seconds each time) will step through the screens.
• Pressing and releasing the M button momentarily and repeatedly (< 2
seconds each time) will step back through the screens.
• If no button is pressed during a 2 minute period, operation will revert to the
Free Surface Main or Watch Default Time screen.
• Pressing the L button will operate the Backlight.
LOG 1, information includes (Fig. 36):
> Graphic No with the dive number (1 to 99) for that day
> Max Depth with MAX and FT (or M) icons
> Log (book) icon
> Pre Dive SI (min:sec, hr:min if > 59:59) the dive began
with SURF and TIME icons, blank if Dive #1
> Elapsed Dive Time (min:sec) with DIVE and TIME icons
Fig. 36 - LOG 1