42
HBI. 1011. 4138500_00
29. TECHNICAL DATA
U.M. HBI080C HBI100C HBI120C HBI140C HBI160C
Cooling capacity
1
(nominal) kW 9.05 10.5 14 15 15.5
Input power
1
(nominal) kW 2.50 3.14 3.68 4.29 4.63
EER
1
3.62 3.34 3.8 3.5 3.35
Cooling capacity
2
(nominal) kW 6.5 8.0 10 11 11.5
Input power
2
(nominal) kW 2.50 3.08 3.45 3.93 4.6
EER
2
2.6 2.6 2.9 2.80 2.5
Heating capacity
1
(nominal) kW 8.5 10 12 13.5 16
Input power
1
(nominal) kW 2.10 2.50 2.79 3.21 3.95
COP
1
4.00 4.00 4.3 4.2 4.00
Heating capacity
2
(nominal) kW 8.0 9.0 11.5 12.5 14
Input power
2
(nominal) kW 2.54 2.90 3.38 3.73 4.59
COP
2
3.15 3.1 3.4 3.35 3.05
Rated Input Cooling
(without electric resistances )
kW 5 5 6.6 6.6 7
Rated Input Heating
(without electric resistances )
kW 4.6 4.6 5.5 5.5 6
OUTDOOR UNIT
Electric Power Supply 230V ~ 50Hz
Air flow rate m³/h / / 6398 6398 6398
n°fans n° 1 1 2 2 2
R410A Refrigerant Load kg 2 2 3,3 3,3 3,3
Sound pressure dB(A) 57 57 57 57 60
Sound pressure dB(A) 59 59 59 59 62
Cooling connections
Liquid Ø 9,52(3/8”) 9,52(3/8”) 9,52(3/8”) 9,52(3/8”) 9,52(3/8”)
Gas Ø 15,9(5/8”) 15,9(5/8”) 15,9(5/8”) 15,9(5/8”) 15,9(5/8”)
Type Ø flare
INDOOR UNIT HBI080E HBI100E HBI120E HBI140E HBI160E
Input Power Indoor Unit* W 245 245 245 245 245
Pump
Input Power Max W 205 205 205 205 205
Speed n° 3 3 3 3 3
Electric resistances power ** kW 3+3 3+3 3+3 3+3 3+3
Total Input Power
with Electric resistances
W 6245 6245 6245 6245 6245
Hydraulic connections (In/Out) - (Male) Ø G1" G1" G1" G1" G1"
Expansion Vessel capacity l 10
Electric Power Supply 230V ~ 50Hz
Outlet water temperature
1
°C 18 ÷ 25
Outlet water temperature
2
°C 7 ÷ 25
Outlet water temperature
1
°C 25 ~ 45
Outlet water temperature
2
°C 25 ~ 55
Sound pressure dB(A) 31
Cooling connections
Liquid Ø 9,52(3/8”) 9,52(3/8”) 9,52(3/8”) 9,52(3/8”) 9,52(3/8”)
Gas Ø 15,9(5/8”) 15,9(5/8”) 15,9(5/8”) 15,9(5/8”) 15,9(5/8”)
Type Ø flare
- Inlet/outlet water temperature 23°C / 18°C
- External air temperature 35°C D.B. / 24°C W.B.
- Inlet/outlet water temperature 12°C / 7°C
- External air temperature 35°C D.B. / 24°C W.B.
- Inlet/outlet water temperature 30°C / 35°C
- External air temperature 7°C D.B. / 6°C W.B.
- Inlet/outlet water temperature 40°C / 45°C
- External air temperature 7°C D.B. / 6°C W.B.
Cooling:
Heating (without electric resistances):
Cooling:
Heating (without electric resistances):
1
-
Floor system
2- Fancoil
2- Fancoil1
-
Floor system
measured at 1m in semianechoic chamber
measured at 1,4m in semianechoic chamber
DHW outlet temperature
* Pump - Input Powe Max + Auxiliary
** Electric resistances 2 step ON/OFF control panel
*** With electric resistances/without electric resistances 40 ÷ 50°C