EasyManuals Logo
Home>Agilent Technologies>Portable Generator>83640B

Agilent Technologies 83640B Service Guide

Agilent Technologies 83640B
603 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #140 background imageLoading...
Page #140 background image
2.
On
the
syn
thesizer,
press:
4
CW
5
The rst
center
frequency in
Table
2-17.
For
the 83623B
/24B only:
Set
the
p
o
w
er
lev
el
to
0
dBm
by
pressing:
4
PO
WER
LEVEL
5
4
0
5
4
dBm
5
F
or all
other syn
thesizers:
Set
the p
ow
er lev
el
to
0
9.9
dBm
b
y
pressing:
4
POWER
LEVEL
54
0
9.9
54
dBm
5
Then,
for
all
syn
thesizers:
Press:
FREQUENCY
4
MENU
5
NN
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
NN
NN
NN
NN
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Up/Dn
Size
CW
4
50
5
4
MHz
5
3. On
the sp
ectrum analyzer,
set:
Center
Frequency: The
same frequency
set
in
step
2
Frequency
Span:
100
Hz
Reference Level:
0 dBm
Marker:
On
Center
Frequency
Step
Size:
50
MHz
T
able
2-17.
Pulse
On/Off
Center
Frequencies
Cen
ter
F
requency
(GHz)
Pulse
On/O
Ratio
1.0
1
6.0
9.0
20.0
22.0
1
1
Disregard if
bey
ond
y
our
syn
thesizer's
capabilit
y
.
4.
On
the
sp
ectrum
analyzer:
a.
T
une
cen
ter
frequency
to
cen
ter
the
signal
on
the displa
y.
b. Set
the
mark
er
to
highest
p
eak.
c.
Note
the
marker
amplitude.
5.
On
the
syn
thesizer,
turn
on
the
external
pulse.
Press:
4
MOD
5
N
N
N
NN
NN
NN
NN
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
NN
NN
NN
NN
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
NN
NN
NN
Pulse
On/Off
Extrnl
(asterisk
on)
or,
for
synthesizers
with
Option
002,
press:
4
MOD
5
N
N
N
N
N
N
N
N
NN
N
N
N
N
N
N
N
N
N
N
N
NN
N
N
N
N
N
N
N
N
N
Pulse Menu
N
N
N
N
N
N
N
N
NN
N
N
N
N
N
N
N
N
N
N
N
NN
N
N
N
N
N
N
N
N
N
N
NN
N
N
N
N
N
N
N
N
N
N
N
NN
N
N
Pulse On/Off Ext
(asterisk on)
6. On the spectrum analyzer set the
reference lev
el to
0
70 dBm.
7. Set the mark
er to the highest peak and note the maxim
um mark
er amplitude.
8. The dierence bet
ween the mark
er v
alue
in step 4 and the mark
er v
alue in step 7 is the
pulse on/o
ratio. Record this v
alue in T
able 2-17
.
9. On the spectrum analyzer, set the reference lev
el to 0 dBm.
10. On the syn
thesizer, turn o
external pulse:
4
MOD
5
NNNNNNNNNNNNNNNNNN
NNNNNNNNNNNNNNNNNNNNNNNNN
NNNNNNNNNNNNNNNN
Pulse On/Off Extrnl
(asterisk o )
or, for synthesizers with Option 002, press:
4
MOD
5
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Pulse Menu
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Pulse On/Off Ext
(asterisk o )
11. Repeat steps 2 through 10 for the remaining synthesizer and sp ectrum analyzer
frequencies in Table 2-17 with the following changes to step 7 when testing 6.0 GHz:
Agilent 8360 Performance Tests
Pulse Modulation On/Off Ratio
2-53

Table of Contents

Other manuals for Agilent Technologies 83640B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 83640B and is the answer not in the manual?

Agilent Technologies 83640B Specifications

General IconGeneral
BrandAgilent Technologies
Model83640B
CategoryPortable Generator
LanguageEnglish

Related product manuals