Key Reference 5
N9342C/43C/44C User’s Guide 123
Rel StopAmpt
Key access: [MEAS] > {SEM} > {Offset/Limits} > {More}
Enters a relative level limit at Stop Freq ranging
from –150.00 to +50.00 dBc with 0.01 dB
resolution, and to toggle this function between
Couple and Man. If set to Couple, this is coupled to
Rel Start to make a flat limit line. If set to Man, Rel
Start and Rel Stop you can enter different values to
make a sloped limit line.
Meas BW
Key access: [MEAS] > {SEM} > {Offset/Limits} > {More}
Specifies the bandwidth to use when measuring the
offset. When using the front panel, only the
currently selected offset is affected. All the offsets
are affected when remote control. This is the
multiplier applied to the resolution bandwidth to
determine the bandwidth to integrate when
calculating the power. Meas BW is now restricted
to be 1 and not changeable.
Fail Mask
Key access: [MEAS] > {SEM} > {Offset/Limits} > {More}
Displays the menu to select one of the following
logic keys for fail conditions between the
measurement results and the test limits:
• Absolute
Sets the limit test to show Fail if one offset is
larger than the corresponding limit for Abs Start
and/or Abs Stop. This is the default selection for
each offset for BTS measurements.
•Relative
Sets the limit test to show Fail if one offsets
spectrum emission mask measurement results is
larger than the corresponding limit for Rel Start
and/or Rel Stop.
• Abs AND Rel