MND172201 P a g e | 11 Software Revision 1.4.1
Seed Sensor and Legend Loop Cable Installation
Select a Seed Sensor mounting location near the distributor.
Mount the Seed Sensors in the hose above the implement
chassis to protect the Seed Sensors and cables from field
debris damage.
Secure the Seed Sensors in the hose using metal hose clamps
on each side (Agtron Part# 400TRHS16, not included).
Select a seed sensor on the far left of the machine to be
sensor #1.
Leave the female plug of this sensor unplugged, but connect
the male plug to the sensor beside it.
This will be sensor #2.
Continue connecting sensor #2 to sensor #3 and so on, until
all sensors on the manifold are connected.
Attach a Legend Loop cable to the male end of the last
sensor on the first manifold.
Connect the male end of the Legend Loop Cable to the
female end of the first sensor on the 2
nd
manifold.
Continue in this fashion until you reach the far right side of
the implement, leaving the male end on the last sensor
unplugged.
Using cable ties, attach all cables to the frame of the
implement. Avoid pinch points such as wing lift and opener
lift points.
The Legend Loop Cables should not be stretched tight
when connected.
Tip:
To help avoid electrical interference
problems, create a figure eight shape
with excess cable before securing.
Tip:
If necessary, apply heat to the hose
ends in order to fit the hose over the
sensor.
Sensors should be mounted on a
relatively straight part of the hose for
best performance.