L06M L06M3-3
3.11 Hydraulic system
- Capacity approx. 53 l
- Hydraulic oil tank 43 l
- Flow 63 l/min.
- Operation pressure
max. 220 bar
- 2 lift cylinders Ø 80 mm
- 1 tip cylinders Ø 80 mm
- 1 steering cylinder Ø 63 mm
- Times according to
DIN ISO 7131
Raise 5,2 s
Lower 3,6 s
Dump 1,0 s
Tilt up 1,0 s
3.12 Fuel supply system
- Capacity
Fuel tank 63 l
3.13 Heating and
ventilation system
- Oil heater Aurora
- Type Teddy
- Heat output
2-speed Q
80
max. 7,5 kW
at V
oil
20 l/min
- Blower output
2-speed max. 475 m³/h
3.14 Full flow suction filter
- Grade of filtration 10 µm nom.
- By-pass reaction
pressure p = 0,25 bar
3.15 Contamination
indicator
3.16 Oil cooler with
thermostat control
- Power 12 kW
- Flow rate 25 l/min
3.11 Equipement hydraulique
- Capacité env. 53 l
- Capacité du réservoir 43 l
- Débit 63 l/min.
- Pression de service
maxi. 220 bar
- 2 vérins de levage Ø 80 mm
-
1 vérin de déversement
Ø 80 mm
- 1 vérin de direction Ø 63 mm
- Temps de fonctionnement
selon DIN ISO 7131
Levage 5,2 s
Descente 3,6 s
Déversement 1,0 s
Redressement 1,0 s
3.12 Alimentation en
carburant
- Capacité du réservoir de
carburant 63 l
3.13 Installation de
chauffage et de ventilation
- Equipement de chauffage
d’huile Aurora
- Type Teddy
- Puissance de chauffe,
2 vitesses Q
80
max. 7,5 kW
pour V
huile
20 l/min
- Puissance de ventilation,
2 vitesses max. 475 m³/h
3.14 Filtre d’aspiration à
débit plein
- Cartouche de filtre 10 µm nom.
- Pression de déclenchement
by-pass p = 0,25 bar
3.15 Indicateur de
colmatage
3.16
Refroidisseur d’huile
avec réglage par thermostat
- Puissance 12 kW
- Débit 25 l/min
3-3
3.11 Hydraulic system
- Capacity approx. 53 l
- Hydraulic oil tank 43 l
- Flow 63 l/min.
- Operation pressure
max. 220 bar
- 2 lift cylinders Ø 80 mm
- 1 tip cylinders Ø 80 mm
- 1 steering cylinder Ø 63 mm
- Times according to
DIN ISO 7131
Raise 5.2 s
Lower 3.6 s
Dump 1.0 s
Tilt up 1.0 s
3.12 Fuel supply system
- Capacity
Fuel tank 63 l
3.13 Heating and
ventilation system
- Oil heater Aurora
- Type Teddy
- Heat output
2-speed Q
80
max. 7,5 kW
at V
oil
20 l/min
- Blower output
2-speed max. 475 m³/h
3.14 Full flow suction filter
- Grade of filtration 10 µm nom.
- By-pass reaction
pressure p = 0,25 bar
3.15 Contamination
indicator
3.16 Oil cooler with
thermostat control
- Power 12 kW
- Flow rate 25 l/min
3.11 Equipement hydraulique
- Capacité env. 53 l
- Capacité du réservoir 43 l
- Débit 63 l/min.
- Pression de service
maxi. 220 bar
- 2 vérins de levage Ø 80 mm
-
1 vérin de déversement
Ø 80 mm
- 1 vérin de direction Ø 63 mm
- Temps de fonctionnement
selon DIN ISO 7131
Levage 5,2 s
Descente 3,6 s
Déversement 1,0 s
Redressement 1,0 s
3.12 Alimentation en
carburant
- Capacité du réservoir de
carburant 63 l
3.13 Installation de
chauffage et de ventilation
- Equipement de chauffage
d’huile Aurora
- Type Teddy
- Puissance de chauffe,
2 vitesses Q
80
max. 7,5 kW
pour V
huile
20 l/min
- Puissance de ventilation,
2 vitesses max. 475 m³/h
3.14 Filtre d’aspiration à
débit plein
- Cartouche de filtre 10 µm nom.
- Pression de déclenchement
by-pass p = 0,25 bar
3.15 Indicateur de
colmatage
3.16
Refroidisseur d’huile
avec réglage par thermostat
- Puissance 12 kW
- Débit 25 l/min