79
2. DiagnosticCodesChart
Whenaproblemoccurs,adiagnosticcodesuchas“LMT”or“ERR”willappearonthedigitaldisplay,and
thenathreedigitnumberrelatedtothediagnosticcodewillappear.
Forfurtherinformationofthediagnosticcodeandnumber,refertotablebelow.
Table12‒1 DiagnosticCodesChart
Code
Number
Description Causes Countermeasures
LMT 001 Tiltwarning
(Travellimitation)
Boomidsraisedupmorethan
45degreesorextended,andthe
machineistiltedmorethan4.5
degrees.
Lowertheboom.
Retracttheboom.
Movetolevelsurface.
LMT 005 Overloadwarning Platformisoverloaded. Reducetheloadonplatform.
LMT 009 Enableswitchdefer
error
1.Footswitchispushedwhile
joystickisalreadyoperated.
1.Releasethejoystickandfoot
switch.
2.Enableswitchisturnedonwhile
boomfunctionswitchisalready
operated.
2.Releasetheboomfunction
switchandenableswitch.
LMT 211 OperationTime-out
(Upper,Footswitch)
1.Footswitchwasalreadyoperated
whenturningKeyswitchon
orpullingupEmergencystop
button.
1.ReleasetheFootswitch.
2.Footswitchisoperatedmore
than20secondswithout
operatingJoysticks/function
switches.
2.ReleasetheFootswitch.
LMT 212 OperationTime-out
(Upper,Traveljoystick)
1.Traveljoystickwasalready
operatedwhenturning
Keyswitchonorpullingup
Emergencystopbutton.
1.ReleasetheTraveljoystick.
2.Traveljoystickisoperated
morethan20secondswithout
operatingFootswitch.
2.ReleasetheTraveljoystick.
LMT 213 OperationTime-out
(Upper,Steeringlever)
1.Steeringleverwasalready
operatedwhenturning
Keyswitchonorpullingup
Emergencystopbutton.
1.ReleasetheSteeringlever.
2.Steeringleverisoperated
morethan20secondswithout
operatingFootswitch.
2.ReleasetheSteeringlever.
LMT 221 OperationTime-out
(Lower,Enableswitch)
1.Enableswitchwasalready
operatedwhenturning
Keyswitchonorpullingup
Emergencystopbutton.
1.ReleasetheEnableswitch.
2.Enableswitchisoperated
morethan20secondswithout
operatingfunctionswitches.
2.ReleasetheEnableswitch.
LMT 224 OperationTime-out
(Lower,Emergency
pumpswitch)
1.Emergencypumpswitchatlower
controlwasalreadyoperated
whenturningKeyswitchonor
pullingupEmergencystopbutton.
1.ReleasetheEmergencypump
switch.
2.Emergencypumpswitchatlower
controlisoperatedmorethan
20secondswithoutoperating
functionswitches.
2.ReleasetheEmergencypump
switch.