1
1. ElectrocutionHazards
DANGER
•Thismachineisnotelectricallyinsulated.
Donotusethemachinenearelectric
powerlines.
M07Y9102
Fig.1‒1
•Keepasafedistancefromelectricpower
linesandapparatus.Forsafedistance,
checkyournationalorlocalregulations.If
nonationalorlocalregulationisavailable,
usethetablebelow.
Table1‒1 MinimumSafeApproachDistance
Voltage
(PhasetoPhase)
MinimumApproach
Distance
0to300V AvoidContact
over300Vto50kV 3.05m
over50kVto200kV 4.60m
over200kVto350kV 6.10m
over350kVto500kV 7.62m
over500kVto750kV 10.67m
over750kVto1000kV 13.72m
•Keepawayfromthemachineifitcontacts
energizedpowerlines.Untilenergized
powerlinesareshutdown,anypersons
intheplatformmustnotoperatethe
machineandanypersonsontheground
mustnottouchthemachine.
WARNING
•Donotusethemachineduringlightning
orstorms.Stopoperationinbadweather.
•Donotusethemachineasagroundfor
welding.
2. TipOverHazards
•Donotexceedtheplatformcapacityas
indicatedontheserialnumberplate.
M085E204
Fig.1‒2
•Donotplacethingssuchassteelbeamsor
powerlinesacrosstheplatform,anduse
theboomtoliftthem.
M07Y9603
Fig.1‒3
•Donotusetheboomorplatformto
pushorpullpowerlinesorotherobjects.
Pressingtheboomorplatformhard
againstthemcouldcausethemachineto
tipoverorbedamaged.
SafetyRules