Page 56
5.5 Machine stop
5.5.1 Normal stop
During the normal stop of the machine, if you release the controls, the operation is stopped. Stop occurs within a time limit set in
the factory, which guarantees smooth braking.
5.5.2 Emergency stop button
Should it be necessary, the operator may immediately stop all machine functions on both platform and ground control panel.
On the platform control panel press the emergency stop button and the machine is turned off.
On the ground control panel:
Press the emergency stop button on the ground control panel and the machine will be turned off.
By pulling out the power connector (Figure 5-5) (battery side) the machine power is cut out (power circuit cut-out).
To resume the operations:
On the platform control panel turn the emergency stop button by a ¼ of turn clockwise.
On the ground control panel turn the emergency stop button by a ¼ of turn clockwise and insert the connector thoroughly to
power the machine again.
5-5: Power connector “X” series
Power connector “XS E RESTYLING” series