Use and Maintenance Manual – Series X – XS E RESTYLING
Red led flashing for a few seconds
Battery charger self-diagnostic phase
Indicates the first and second charging phase
Indicates the equalization of the charging phase
Indicates that charging is over; buffer charge active
With the battery charger ON, the machine is automatically off.
To disconnect the battery charger from the power source, disconnect the machine from the electric line.
WARNING!
Before using the machine check that the power cord of the battery charger is disconnected.
7.4.4 Battery charger: fault report
The flashing LED on the battery charger indicator described in the previous paragraph indicates that an alarm situation has
occurred:
Red led constantly
flashing
No connection with the battery
Check the connections with the battery
Connections with the battery inverted
Red and yellow led blinking
Check that battery was not disconnected during
charging phase
Check the fluid level
(for pb-acid batteries only)
7.4.5 Battery replacement
Replace the old batteries only with models of the same voltage, capacity, dimensions and mass.
Batteries must be approved by the manufacturer.
Do not dispose of batteries in the environment after replacement. Comply with the current local standards.
AS THIS OPERATION IS VERY IMPORTANT IT IS TO BE CARRIED OUT BY SKILLED TECHNICIANS ONLY.
CALL THE TECHNICAL SUPPORT