Interface connector assembly 34 (38)
Installation Manual T-Rx 1000/1500 FSK12 FSK12 Version: B4 Document-ID: 945814-000 Author: SH
15.3.2 Interconnection of the coupling
15.3.2.1 Mating
The connector has a lever/slide mating/ unmating aid. In delivery condition the lever is in nal
locking position. Before interconnection, the lever must be moved into pre locking position.
Take care that the right polarization and coding ts to the counterpart. It is shown in Figure 24.
When polarization and coding of both parts t to gether the pivots of the tab housing will disap-
pear in the receptacle connector.
Now, it is possible to interconnect the system by moving the lever down. If polarization and
coding doesn’t t together, it is possible to close the lever, but not to interconnect the system.
Furthermore, as described in chapter 15.3.1.3 pay at tention that the locking slide is in nal
locked posi tion. Otherwise, the lever might be destroyed during mat ing process caused by to
high handling force!
The correct locking is signalized by a “click” noise and a haptin snapping in (see Figure 23).
Figure 23. Mating
Polarization
Coding
Marking
Figure 24. Polarization
15.3.2.2 Unmating
To disconnect the connector, the lever has to be brought
into the pre locked position. The correct position is sig-
nalized by a “click” noise.